15
CLUSTER
SWITCH
Ground
INSPECTION
Check for continuity
between
the terminals
by using
a circuit
tester or ohmmeter.
Rear Wiper and Washer Switch
-1
M:
Indicates
continuity
Rear Defroster
Switch
WI
M:
Indicates
continuity
Panel Light Control
Switch
Connect
the 12V probe to the "b" terminal
and the
ground
to the "a"
terminal.
Check
that the "c" terminal
voltage
to the ground
changes
with the turning
angle of the control
knob.
Control
knob Minimum
- Maximum
Voltage OV c* 12V
Caution
a) Do not misconnect
the electrical
source to
the terminals.
b) Never supply 12V to the "c" terminal. (Con-
troller will burn out Instantly.)