Mazda 323 1988 Workshop Manual page 311

Mazda 323 1988
Hide thumbs Also See for 323 1988:
Table of Contents

Advertisement

FUEL SYSTEM
4B
How to Connect
Multi-Pressure
Tester
Warning
Before connecting
SST, release the fuel pres-
sure from the fuel line to reduce the possibll-
ity of injury or fire. (Refer to page 48-37)
1. Disconnect
the battery
negative
cable.
2. Disconnect
the fuel main hose from the pressure
regulator
3. Connect
SST
between
fuel main
hose and pres-
sure regulator
using adapter.
Caution
Do not reverse
the adapter
connection.
4. Disconnect
the vacuum
hose from the pressure
regulator
control solenoid
valve, and connect
SST
vacuum
hose using a three-way
joint.
5. Connect
the battery
negative
cable.
6. Connect
SST
to the battery.
7. Connect
the terminals
of the test connector
(yel-
low connector)
with a jumper
wire. Turn the igni-
tion switch ON to operate
the fuel pump.
8.
Check
for fuel leaks.
Caution
After checking fuel leakage, turn the ignition
switch OFF and disconnect
the jumper
wire
from the service
connector.
323
Revised
10187
48-39