15
TURN
AND HAZARD
SIGNAL
LIGHT
FLASHER UNIT
Operation
check
1, Apply 12V to the "B" terminal
of the unit and con-
nect "E"
terminal
to the ground.
2. Confirm
that the two paralleled
lamps
come
on
when connected
between the "L" terminal
and the
ground.
Caution
Do no reverse
the polarity
of the electrical
source to the terminals.
15-48