Mazda 323 1988 Workshop Manual page 185

Mazda 323 1988
Hide thumbs Also See for 323 1988:
Table of Contents

Advertisement

RADIATOR
CAP,
ELECTRIC
FAN MOTOR
3A
RADIATOR
CAP
INSPECTION
Radiator
Cap Valve
1. Remove
foreign
material
(water residue,
etc.) from
between
the radiator cap valve and the valve seat.
2. Attach the radiator
cap with SST to a tester.
Ap-
ply
pressure
gradually
to
74-103
kPa
(0.75-l
.05 kg/cm',
1 l-15
psi).
3. Wait about
IO seconds,
and check
whether
the
pressure
has decreased.
The cap is normal
if the pressure
is maintained
for
about
10 seconds.
Negative-Pressure
Valve
1, Pull the negative-pressure
valve to open it. Check
that it closes
completely
when released.
2. Check
for
damage
on the
contact
surfaces,
cracked
or deformed
seal packing.
Replace
the
radiator
cap if necessary.
ELECTRIC
FAN MOTOR
INSPECTION
1. Disconnect
the fan motor
connectors
2. Connect
an ammeter
and battery to the fan motor
connectors.
3. Check
to be sure that the fan motor
operates
smoothly
at the standard
current
or less.
Standard
current:
5.6-7.6
Amperes
(MTX)
10.0-l
1.0 Amperes
(ATX)
4. If the fan motor
is faulty,
replace
it.
3A-5