3. Insert the inhalation outlet 155 into the multistep flow selector 161.
155
161
4. Use the torque wrench to tightly screw in the inhalation outlet 155
in the multistep flow selector 161.
When doing so, note: Loctite 413 must harden according to the
manufacturer's specifications.
5. Loosen the hand-screwed connection 177 at the top part of the
counter tool 400.
6. Unscrew the hand-screwed connection 177 from the bottom part
of the counter tool 400 by hand.
7. Remove the hand-screwed connection 177 of the pressure reducer
from the counter tool 400.
8. Remove the top part of the counter tool 400 from the bottom part
of the counter tool 400.
9. Loosen the bottom part of the counter tool 400 from the vise and
remove.
10.Fit the sieve 157 and the sealing disks 158 in the inhalation
outlet 155
inhalation outlet", page
11.Fit the pressure screw 156 in the inhalation outlet 155
(see "14.5.2 Fitting the pressure screw in the inhalation outlet",
page
12.Fit the O-ring 176 in the connecting bolt 175
(see "14.7.2 Fitting the O-ring in the connecting bolt", page
14.13 Replacing the multistep flow selector
assembly
Required tools
• Cover clamping device 401
• Cover screw-in device 402
• Counter cap 404
• Torque wrench 8 Nm ± 2 Nm
• Vise
• Pressure piece for the cover screw-in device 403
Contents
Repairs to OXYWAY Fast I, OXYWAY Fast I+, OXYWAY Fast III
(see "14.6.2 Fitting the sieve and sealing disks in the
90).