Weinmann OXYWAY Fix I Service Manual page 4

Pressure reducer
Table of Contents

Advertisement

Table of Contents
4
EN
OXYWAY
Back
14 Repairs to OXYWAY Fast I,
15 Repairs to OXYWAY Fast II ...................... 125
Forward
OXYWAY Fast I+, OXYWAY Fast III ............ 82
14.1 General instructions ...................................................... 82
14.2 Sequence of repair steps ............................................... 82
14.3 Assemblies ................................................................... 88
14.4 Replacing a label .......................................................... 88
14.5 Replacing the pressure screw in the inhalation outlet .... 89
14.6 Replacing the sieve and nozzle plate
in the inhalation outlet ................................................. 90
14.7 Replacing the O-ring in the connecting bolt ................... 90
14.8 Replacing the disposable filter ...................................... 91
14.9 Replacing the connecting bolt ....................................... 92
14.10Replacing the hand-screwed connection ....................... 93
14.11Replacing the rib filter .................................................. 94
14.12Replacing the inhalation outlet ..................................... 95
14.13Replacing the multistep flow selector assembly ............. 97
14.14Replacing the spring for the piston ............................... 99
14.15Replacing the threaded locking pin ............................ 100
14.16Replacing the piston .................................................. 100
14.17Disassembling/assembling the multistep flow
selector assembly ...................................................... 101
14.18Replacing the O-ring in the contents indicator ............ 104
14.19Replacing the contents indicator ................................ 105
14.20Disassembling/assembling the orifice plate assembly .. 106
14.21Replacing the threaded pin in the multistep
flow selector .............................................................. 108
14.22Replacing the multistep flow selector ......................... 109
14.23Replacing the balls ..................................................... 109
14.24Replacing the springs ................................................. 110
14.25Replacing the needle ................................................. 111
14.26Replacing the sliding ring ........................................... 111
14.27Disassembling/assembling the cover assembly ............ 112
14.28Replacing the O-ring in the housing cover .................. 117
14.29Replacing the O-rings in the multistep flow selector .... 119
14.30Replacing the housing cover ...................................... 120
14.31Replacing the multistep flow selector ......................... 120
14.32Replacing the union nut ............................................. 121
14.33Replacing the holder for the orifice plate .................... 122
14.34Replacing the orifice plate .......................................... 123
14.35Replacing the slide disk .............................................. 123
15.1 General instructions .................................................... 125
15.2 Sequence of repair steps ............................................. 125
15.3 Assemblies ................................................................. 131
15.4 Replacing a label ........................................................ 131
15.5 Replacing the pressure screw in the inhalation outlet .. 132
15.6 Replacing the sieve and nozzle plate
in the inhalation outlet ............................................... 133
15.7 Replacing the pressure screw in the pressure outlet ..... 133
15.8 Replacing the O-ring in the connecting bolt ................. 134
Contents
Previous page
Next page

Advertisement

Table of Contents
loading

Table of Contents