Group 5

5.4.5 Interface X3 (Outputs)

8 outputs which can be freely selected are available for special functions. The
outputs 1-3 are predefined as a standard and should be not changed.
Output 1 = Print stop error
Output 2 = Refill warning
Plug assignment:
Specifications Output 1-8:
Parameter
Driver type
Output current
Max. switching frequency
Max. delay time
Turn on resistance
Features
The function allocations of the outputs is carried out with the
software of the JET3 in the menu Settings
Outputs.
You will find a circuit diagram of the interface in the appendix of this
manual!
(1)
All 24V inputs which are designated with (1) are protected by a self-reset fuse with 700mA,
that means the sum of all output currents which are supplied of this 24V should not exceed
700mA.
(2)
Depending on the set function.
Release R1.03e
Transport/Start up
Pin connection:
Pin
Designation
1
Output 1
2
Output 2
3
Output 3
4
Output 4
5
+24V
(1)
6
Reserved
7
Reserved
8
GND
Reserved = Do not connect
Value
24V high side driver
ON = +24V
OFF = high resistance
max. 700mA/output
max 700 mA totally
2 kHz
(2)
100µs
max. 0,28 Ohm
Short-circuit-proof
Overcurrent- and excess temperature –proof
Output 3 = Ready to print
Pin
Designation
9
Output 5
10
Output 6
11
Output 7
12
Output 8
13
Reserved
14
Reserved
15
GND
(1)
Page 39