2
Technology > Pickup / Feed System > Deck/Cassette Pickup Unit > Paper Level Detection
■
Paper Level Detection
Paper level is detected by two Paper Level sensors in each cassette
●
Deck
ight Deck Paper
Right Deck Paper
Level Sensor 2
Level Sensor 1 (PS47)
Left Deck Paper Level
Left Deck Paper
Sensor 1 (PS49)
Level Sensor 2
Full
ON
(100%~50%)
Half
ON
(50%~25%)
Few
OFF
(25% or less)
2
Technology > Pickup / Feed System > Deck/Cassette Pickup Unit > Paper Level Detection
Paper Level
Detection Lever 1
Control
(PS48)
Panel
Screen
Paper Level
Detection Lever 2
Display
(PS50)
OFF
ON
ON
T-2-74
T-2-74
Paper
Right Deck Paper Level Sensor 1 (PS47)
Left Deck Paper Level Sensor 1 (PS49)
Deck Detection Lever
Right Deck Paper Level
Sensor 2 (PS48)
Left Deck Paper Level
Sensor 2 (PS50)
Deck Lifter
Half (50%~25%)
ON
ON
Full
(100%~50%)
F-2-167
F-2-167
Paper
Few (25% or less)
Paper
F-2-169
F-2-169
2-135
ON
OFF
F-2-168
F-2-168
OFF
ON
F-2-170
F-2-170
2-135