9. FUNCTION SETTING (ECM CUSTOMIZING)
1) On the «Main Menu» display screen, select the {Each System Check} and press the [YES] key.
2) On the «System Selection Menu» display screen, select the {Integ. Unit mode} and press the [YES] key.
3) On the «Integ. Unit mode failuer diag» display screen, select the {ECM customizing} and press the [YES]
key.
4) Change the setting with UP/DOWN key and press the [YES] key.
• List of function setting item (ECM customizing)
No.
Data
1
Off delay time
2
Auto-lock time
3
Rr defogger op. mode
4
Wiper deicer op. mode
5
Security Alarm Setup
6
Impact Sensor Setup
7
Alarm monitor delay setting
8
Lockout prevention
9
Impact sensor (OP)
10
Siren setting
Subaru Select Monitor
Initial
setting
Customize setting
value
Setting
OFF
Normal
Short
Normal
Long
30 sec.
0 — 60 seconds
15 min.
15 min.
Continuation
15 min.
15 min.
Continuation
ON
OFF
OFF
ON
OFF
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
OFF
ON
OFF
OFF
LAN(diag)-21
LAN SYSTEM (DIAGNOSTICS)
Remarks
Delay time below can be selected by setting.
After door closed
0 sec.
3 sec.
5 sec.
8 sec.
Workable when Auto locking is set to "ON" and Automatic
locking setup is "ON"
Time can be changed by 10 seconds: 0 (OFF) — 60 (maxi-
mum).
Rear defogger stops in 15 minutes automatically after
switch is turned to ON.
Rear defogger repeats active condition for 15 minutes and
inactive condition for 2 minutes until switch is turned to OFF.
Wiper deicer stops in 15 minutes automatically after switch
is turned to ON.
Wiper deicer repeats active condition for 15 minutes and
inactive condition for 2 minutes until switch is turned to OFF.
Security alarm (horn or siren) in active condition
Security alarm in inactive condition
Workable when Impact Sensor Setup is set to "ON"
Impact sensor in active condition
Impact sensor in inactive condition
(Set Impact Sensor Setup of model without impact sensor
to "OFF".)
After doors are locked by keyless entry system operated,
Alarm monitor starts in following time.
Delay time is 30 seconds.
Delay time is 0 second.
Lockout prevention in active condition
(Lockout prevention does not operate if safety knob is
locked by hand.)
Lockout prevention in inactive condition
Vehicle is controlled in impact sensor equipped mode. (Set
Impact sensor to "OFF" in model without impact sensor. If
Impact sensor is set to "ON", hazard, horn or siren operate
after doors are locked by keyless entry system operated
(Alarm monitor starting).
Vehicle is controlled in impact sensor no-equipped mode.
Siren sounds when alarm operates.
(Set Siren setting to "OFF" in model without siren. Horn
does not sound if Siren setting is set to "ON".)
Horn sounds when alarm operates.
After key unlock
0 sec.
10 sec.
20 sec.
30 sec.