Chapter 10 Digital KeypadC2000

10-1 Descriptions of Digital Keypad

The default communication format is ASCII 9600, 7, N, 2 in C2000. But the communication format is RTU
19200, 8, N, 2. To enable the communication between C2000 and KPC-CC01, you need to set up the
communication parameters of C2000 before linking the drive and the keypad (KPC-CC01).
Follow the set-up steps below:
Set Pr.09-00 = 1 (the communication address)
Set Pr.09-01 = 19.2 kbps (the COM1 transmission speed)
Set Pr.09-04 = 13 (8, N, 2; RTU) (the COM1 communicatino protocol)
Descriptions of Keypad Functions
Key
Start Operation Key
1. It is only valid when the source of operation command is from the keypad.
2. It can operate the AC motor drive by the function setting and the RUN LED will be ON.
3. It can be pressed again and again at stop process.
Stop Command Key. This key has the highest priority in any situation.
1. When it receives STOP command, no matter if the AC motor drive is in operation or stop
2. The RESET key can be used to reset the drive after the fault occurs.
3. The reasons why the error cannot be reset:
Operation Direction Key
1. This key only controls the operation direction, and will NOT activate the drive. FWD:
2. Refer to the LED descriptions for more details.
ENTER Key
Press ENTER and go to the next level. If it is the last level then press ENTER to execute the
command.
ESC Key
ESC key function is to leave current menu and return to the last menu. It also
return key or cancel key in the sub-menu.
Press menu to return to main menu.
Menu content:
1. Parameter Setup
2. Quick Start
3. Application Selection List
4. Changed List
5. Copy Parameter
6. Fault Record
KPC-CC01
Communication Interface
RJ45 (socket), RS-485 interface
Installation Method
1. Embedded type and can be put flat on the surface of the control box. The front
cover is water proof.
2. Buy a MKC-KPPK model to do wall mounting or embedded mounting. Its
protection level is IP66.
3. The maximum RJ45 extension lead is 5 m (16ft)
4. This keypad can only be used on Delta's motor drive C2000, CH2000 and
CP2000.
status, the AC motor drive needs to execute "STOP" command.
a. Because the condition which triggers the fault is not cleared. When the condition is
cleared, the fault can be reset.
b. Because it's the fault status checking when power-on. When the condition is cleared,
re-power again, and the fault can be reset.
forward, REV: reverse.
Descriptions
7. Language Setup
8. Time Setup
9. Keypad Locked
10. PLC Function
11. Copy PLC
12. Display Setup
10-2
functions
13. Startup Menu
14. Main Page
15. PC Link
16. Start Wizard
as a