Delta C2000 Series User Manual page 698

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

ID*
Display on LCM Keypad
40
Action level
Action time
Fault treatment parameter
Reset method
Reset condition
Record
Cause
Press "STOP" key during
auto-tuning
Incorrect motor capacity (too large
or too small) and parameter setting
Incorrect motor wiring
Motor shaft lock
The electromagnetic contactor is
ON at output side (U/V/W) of the
drive
The load is too large.
Accel./Decel. time is too short
ID*
Display on LCM Keypad
41
Action level
Action time
Fault treatment parameter
Reset method
Reset condition
Record
Cause
PID feedback cable is loose or cut
off
Feedback device failure
Hardware failure
Fault Name
Auto-tuning error
Motor auto-tuning error
(AUE)
Action and Reset
Hardware detection
Immediately act
N/A
Manual reset
Immediately reset
Yes
Re-execute auto-tuning.
Check motor capacity and related parameters.
Set the correct parameters, that is Pr. 01-01–Pr. 01-02.
Set Pr.01-00 larger than motor rated frequency.
Check the wiring.
Remove the cause of motor shaft lock.
Make sure the electromagnetic valve is OFF.
Reduce the load.
Replace the motor with a larger capacity model.
Increase the setting values for Pr. 01-12–Pr. 01-19 (Accel./Decel. time).
Fault Name
PID feedback loss (analog feedback signal is only valid
PID loss ACI (AFE)
when the PID function is enabled)
Action and Reset
When the analog input < 4mA (only detects 4–20mA analog input)
Pr. 08-08
Pr. 08-09
0: warn and keep operation
1: warn and ramp to stop
2: warn and coast to stop
3: warn and operate at last frequency
When Pr. 08-09=3 or 4, AFE is a "Warning". When the feedback signal
Auto
is > 4mA, the "Warning" is automatically cleared.
Manual When Pr. 08-09=1 or 2, AFE is a "Fault". You must reset manually.
Immediately reset
When Pr. 08-09=1 or 2, AFE is a "Fault", and the fault is recorded; when Pr.
08-09=3 or 4, AFE is a "Warning", and the warning is not recorded.
Tighten the terminal.
Replace the cable with a new one.
Replace the device with a new one.
Check all the wiring. If AFE fault still exists, return to the factory for repair.
14-27
Chapter 14 Fault Codes and DescriptionsC2000
Fault Descriptions
Corrective Actions
Fault Descriptions
Corrective Actions