Delta C2000 Series User Manual page 341

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 11 Summary of Parameter SettingsC2000
Pr.
Parameter Name
00-19
PLC command mask
Master frequency command
00-20
(AUTO) source / Source selection
of the PID target
Operation command (AUTO)
00-21
source
00-22
Stop method
00-23
Control of motor direction
Digital keypad frequency command
00-24
memory
00-25
User defined characteristics
Setting Range
bit0: Control command by PLC force control
bit1: Frequency command by PLC force control
bit2: Position command by PLC force control
bit3: Torque command by PLC force control
0: Digital keypad
1: RS-485 communication
2: External analog input (Pr. 03-00)
3: External UP / DOWN terminal (multi-function
input terminal)
4: Pulse input without direction command (Pr.10-16
without direction), use with PG card
5: Pulse input with direction command (Pr. 10-16),
use with PG card
6: CANopen communication card
8: Communication card (does not include CANopen
card)
0: Digital keypad
1: External terminals.
2: RS-485 communication.
3: CANopen communication card
5: Communication card (does not include CANopen
card)
0: Ramp to stop
1: Coast to stop
0: Enable forward / reverse
1: Disable reverse
2: Disable forward
Read only
bit0–3: user defined decimal place
0000b: no decimal place
0001b: one decimal place
0010b: two decimal places
0011b: three decimal places
bit4–15: user defined unit
000xh: Hz
001xh: rpm
002xh: %
003xh: kg
004xh: m/s
11-6
Default
Read
only
0
0
0
0
Read
only
0