Error Display And Handling - Delta C2000 Series User Manual

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

16-7 Error display and handling

Code
ID
PLrA
47
PLrt
49
PLod
50
PLSv
51
PLdA
52
PLFn
53
PLor
54
PLFF
55
PLSn
56
PLEd
57
PLCr
58
PLdF
59
PLSF
60
Descript
RTC time check
Incorrect RTC time
Data writing memory error
Data write memory error during
program execution
Program transmission error
Command error while downloading
program
Program exceeds memory capacity
or no program
Command error during program
execution
Check code error
Program
has
no
command
MC command has been used
continuously more than nine times
Download program error
PLC scan time excessively long
Chapter 16 PLC Function ApplicationsC2000
Recommended handling approach
Turn power on and off when resetting the
keypad time
Turn power on and off after making sure
that the keypad is securely connected
Check whether the program has an error
and download the program again
Restart power and download the program
again
Try uploading again; if the error persists,
sent to the manufacturer for service
Check whether the program has an error
and download the program again
Restart power and download the program
again
Check whether the program has an error
and download the program again
Check whether the program has an error
and download the program again
END
stop
Check whether the program has an error
and download the program again
Check whether the program has an error
and download the program again
Check whether the program has an error
and download again
Check whether the program code has a
writing error and download again
16-131

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents