Chapter 12 Description of Parameter SettingsC2000
Setting procedure of MI8 single-phase pulse input:
Pr. 00-20=4, Pulse input without direction command
Pr.10-01 set as the ppr number of each rotation.
Pr.10-16=5, MI8 single-phase pulse input
MI8 input and PG2 input could both exist at the same time. But PG card Pr. 10-00 and Pr. 10-16
cannot be set as MI8 at the same time.
Electrical Gear A
Electrical Gear B
Settings
 Rotation speed = pulse frequency / encoder pulses (Pr. 10-01) * Electrical Gear A / Electrical
Gear B.
Positioning for Encoder Position
Settings
 Determines the internal position in the position mode.
 Use this with the multi-function input terminal setting = 35 (enable position control).
 When set to 0, it is the Z-phase position of the encoder.
 The setting range is affected by Pr. 10-01 and Pr. 10-02.
Example:
When Pr. 10-01 = 2500, Pr. 10-02 = 1 or 2, the setting range for Pr. 10-19 is -32767–10000.
When Pr. 10-01 = 1024, Pr. 10-02 = 1 or 2, the setting range for Pr. 10-19 is -32767–4096.
When Pr. 10-01 = 2500, Pr. 10-02 = 3, 4 or 5, the setting range for Pr. 10-19 is -32767–2500.
Error Range for Encoder Position Reached
Settings
 This parameter determines the range for the internal positioning position reached.
Example:
When you set the position for Pr.10-19 (Positioning for Encoder Position) and Pr.10-20 to 1000,
it reaches the position if the position is between 990
Filter Time (PG2)
Settings
 When you set Pr. 00-20 to 5 and the multi-function input terminal to 37 (OFF), the system treats
the pulse command as a Frequency command. Use this parameter to suppress the speed
command jump.
1–65535
-32767–2400
0–65535 pulses
0.000–65.535 sec.
1010 after positioning.
12.1-10-6
Default: 100
Default: 0
Default: 10
Default: 0.100