Delta C2000 Series User Manual page 854

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

API
ASIN
133
D
P
Bit device
X
Y
M
K
S
*
D
Notes on operand usage:
Please refer to the function specifications table for each device in
series for the scope of device usage
S: the designated source (binary floating point number). D: the ASIN value result.
ASIN value =sin
The figure below shows the relationship between input data and result:
When X0=On, the ASIN value obtained from the designated binary floating point
number (D1, D0) will be stored in (D11, D10), with the content consisting of a
binary floating point number.
X0
Word device
H
KnX KnY KnM
T
*
-1
DASIN
D0
16-93
Chapter 16 PLC Function ApplicationsC2000
Binary floating point number ASIN operation
16-bit command
C
D
*
32-bit command (9 STEP)
*
DASIN
Continuous
execution type
Flag signal: none
D10
DASINP
Pulse
execution type

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents