9-2 460V Series
Frame Size
Model VFD-_ _ _ C_ _
Rated Output Capacity [kVA]
Rated Output Current [A]
Applicable Motor Output [kW]
Applicable Motor Output [HP]
Overload Capacity
Max. Output Frequency [Hz]
Carrier Frequency [kHz]
Rated Output Capacity [kVA]
Rated Output Current [A]
Applicable Motor Output [kW]
Applicable Motor Output [HP]
Overload Capacity
Max. Output Frequency [Hz]
Carrier Frequency [kHz]
Normal Duty
Input Current [A]
Heavy Duty
Rated Voltage / Frequency
Operating Voltage Range
Frequency Tolerance
Efficiency [%]
Power Factor
Drive Weight [Kg]
Cooling Method
Braking Chopper
DC choke
EMC Filter
EMC-COP01
NOTE
*
1.
: The factory setting is Normal Duty mode.
2. The carrier frequency is default. Increasing the carrier frequency requires a reduction in current. Please refer to Chapter 9-7
Derating Curve of Ambient Temperature.
3. The AC motor drive should operate in derating current when its control method is set to FOC Sensorless, TQC+PG, TQC
sensorless. PM+PG, PM sensorless Please refer to Pr. 06-55 for more information.
4. Select the AC motor drive with capacity one grade larger for the impact load application.
5. The rated input current will be affected by not only Power Transformer and the connection of the reactors on input side, but
also fluctuates with the impedance of power side.
6. For Frame A, B and C, Model VFDXXXC43A is under IP20/NEMA1/UL TYPE1 protection level.
7. For Frame D and above, if the last character of the model is A then it is under IP20 protection level but the wiring terminal is
under IP00 protection level; if the last character of the model is E, it is under IP20/NEMA1/UL TYPE1 protection level.
A
007
015
022
037
2.4
3.2
4.8
7.2
3.0
4.0
6.0
9.0
0.75
1.5
2.2
3.7
1
2
3
5
120% of rated output current: 1 minute for every 5 minutes;
160% of rated output current: 3 seconds for every 30 seconds
2~15 (Default: 8)
2.3
3.0
4.5
6.5
2.9
3.8
5.7
8.1
0.4
0.75
1.5
2.2
0.5
1
2
3
150% of rated output current: 1 minute for every 5 minutes;
180% of rated output current: 3 seconds for every 30 seconds
2~15 (Default: 2)
4.3
5.9
8.7
14
4.1
5.6
8.3
13
3-phase AC 380V~480V ( -15%~+10%), 50 / 60Hz
2.6± 0.3
Natural cooling
VFDXXXC43A: Optional; Frame A~C VFDXXXC43E: Built-in
VFDXXXC43A: Optional; VFDXXXC43E: Built-in
040
055
075
8.4
10
14
10.5
12
18
4.0
5.5
7.5
5
7.5
10
0.00~599.00
7.6
9.6
14
9.5
11
17
3.7
4.0
5.5
5
5
7.5
0.00~300.00
15.5
17
20
14.5
16
19
323~528V
AC
47~63Hz
97.8
>0.98
Fan cooling
Frame A~C: Built-in
Frame A~C: Optional
9-3
Chapter 9 Specification C2000
B
C
110
150
185
220
19
25
30
36
24
32
38
45
11
15
18.5
22
15
20
25
30
2~10 (Default: 6)
18
24
29
34
23
30
36
43
7.5
11
15
18.5
10
15
20
25
2~10 (Default: 2)
26
35
40
47
25
33
38
45
5.4± 1
9.8± 1.5
Table 9-2
300
48
60
30
40
45
57
22
30
63
60