Delta C2000 Series User Manual page 554

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Modbus
R/W
address
2101H
R
2102H
R
Frequency command (XXX.XX Hz)
2103H
R
Output frequency (XXX.XX Hz)
Output current (XX.XX A). When current is higher than 655.35, it shifts the
2104H
R
decimal as (XXX.X A). The decimal can refer to High byte of 211F.
2105H
R
DC BUS Voltage (XXX.X V)
2106H
R
Output voltage (XXX.X V)
2107H
R
Current step number of multi-step speed operation
2108H
R
Reserved
2109H
R
Counter value
210AH
R
Power factor angle (XXX.X)
210BH
R
Output torque (XXX.X %)
210CH
R
Actual motor speed (XXXXX rpm)
210DH
R
Number of PG feedback pulses (0–65535)
210EH
R
Number of PG2 pulse commands (0–65535)
210FH
R
Power output (X.XXX kW)
2116H
R
Multi-function display (Pr. 00-04)
Maximum Operation Frequency (Pr. 01-00) or Maximum User-defined Value
(Pr. 00-26)
When Pr. 00-26 is 0, this value is equal to Pr. 01-00 setting
211BH
R
When Pr. 00-26 is not 0, and the command source is keypad, this value =
Pr. 00-24 * Pr. 00-26 / Pr. 01-00
When Pr. 00-26 is not 0, and the command source is 485, this value = Pr.
09-10 * Pr. 00-26 / Pr. 01-00
211FH
R
High byte: decimal of current value (display)
Status monitor read only (22xx)
Modbus
RW
address
Display output current (A). When current is higher than 655.35, it shifts the
2200H
R
decimal as (XXX.X A). The decimal can refer to High byte of 211F.
2201H
R
Display counter value (c)
2202H
R
Actual output frequency (XXXXX Hz)
2203H
R
DC BUS voltage (XXX.X V)
2204H
R
Output voltage (XXX.X V)
AC motor drive operation status
bit1–0
00B: Drive stops
01B: Drive decelerating
10B: Drive standby
11B: Drive operating
bit2
1:JOG Command
Operation Direction
bit4–3
00B: FWD run
01B: From REV run to FWD run
10B: From FWD run to REV run
11B: REV run
bit8
1: Master frequency controlled by communication interface
bit9
1: Master frequency controlled by analog/external signal
bit10
1: Operation command controlled by communication interface
bit11
1: Parameter locked
bit12
1: Enable to copy parameters from keypad
bit15–13 Reserved
12.1-09-9
Chapter 12 Description of Parameter SettingsC2000
Function
Function