V Series - Delta C2000 Series User Manual

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 9 Specification C2000

9-1 230V Series

Frame Size
Model VFD-_ _ _C_ _
Rated Output Capacity [kVA]
Rated Output Current [A]
Applicable Motor Output [kW]
Applicable Motor Output [HP]
Overload Capacity
Max. Output Frequency [Hz]
Carrier Frequency [kHz]
Rated Output Capacity [kVA]
Rated Output Current [A]
Applicable Motor Output [kW]
Applicable Motor Output [HP]
Overload Capacity
Max. Output Frequency [Hz]
Carrier Frequency [kHz]
Normal Duty
Input Current [A]
Heavy Duty
Rated Voltage / Frequency
Operating Voltage Range
Frequency Tolerance
Efficiency [%]
Power Factor
Drive Weight [Kg]
Cooling Method
Braking Chopper
DC choke
EMC Filter
EMC-COP01
NOTE
*
1.
: The factory setting is Normal Duty mode.
2. The carrier frequency is default. Increasing the carrier frequency requires a reduction in current. Please refer to Chapter 9-7
Derating Curve of Ambient Temperature.
3. The AC motor drive should operate in derating current when its control method is set to FOC Sensorless, TQC+PG, TQC
sensorless. PM+PG, PM sensorless Please refer to Pr. 06-55 for more information.
4. Select the AC motor drive with capacity one grade larger for the impact load application.
5. The rated input current will be affected by not only Power Transformer and the connection of the reactors on input side, but
also fluctuates with the impedance of power side.
6. For Frame D and above, if the last character of the model is A then it is under IP20 protection level but the wiring terminal is
under IP00 protection level; if the last character of the model is E, it is under IP20/NEMA1/UL TYPE1 protection level.
A
007
015
022
037
2.0
3.2
4.4
6.8
5
8
11
17
0.75
1.5
2.2
3.7
1
2
3
5
120% of rated output current: 1 minute for every 5 minutes;
160% of rated output current: 3 seconds for every 30 seconds
2~15 (Default: 8)
1.9
2.8
4.0
6.4
4.8
7.1
10
16
0.4
0.75
1.5
2.2
0.5
1
2
3
150% of rated output current: 1 minute for every 5 minutes;
180% of rated output current: 3 seconds for every 30 seconds
2~15 (Default: 2)
6.4
12
16
20
6.1
11
15
18.5
3-phase AC 200V~240V (-15% ~ +10%),50 / 60Hz
2.6 ± 0.3
Natural
cooling
Frame A~C: Built-in
Frame A~C: Optional
B
C
055
075
110
150
185
220
10
13
20
26
30
25
33
49
65
75
5.5
7.5
11
15
18.5
7.5
10
15
20
25
0.00~599.00
2~10 (Default: 6)
9.6
12
19
25
28
24
31
47
62
71
3.7
5.5
7.5
11
15
5
7.5
10
15
20
0.00~300.00
2~10 (Default: 2)
28
36
52
72
83
26
34
50
68
78
170~264V
AC
47~63Hz
97.8
>0.98
5.4 ± 1
9.8 ± 1.5
Fan cooling
Frame A~F: Optional
Frame A~F: Optional
9-2
D
E
300
370
450
550 750
36
48
58
72
86
102
90
120
146
180
215 255
22
30
37
45
55
75
30
40
50
60
75
100
2~9 (Default: 4)
34
45
55
68
81
96
86
114
139
171
204 242
19
22
30
37
45
55
25
30
40
50
60
75
2~9 (Default: 2)
99
124
143
171
206 245
95
118
136
162
196 233
98.2
38.5 ± 1.5
64.8 ± 1.5
Frame D~F: Optional
Frame D~F: Built-in
F
900
138
346
90
120
131
329
75
100
331
315
86.5 ± 1.5
Table 9-1