Pr.
Parameter Name
00-03
Start-up display selection
Content of multi-function display
00-04
(user-defined)
Chapter 11 Summary of Parameter SettingsC2000
Setting Range
6: Reset PLC (including CANopen Master Index)
7: Reset CANopen Index (Slave)
9: Reset all parameters to defaults with base
frequency at 50 Hz
10: Reset all parameters to defaults with base
frequency at 60 Hz
0: F (frequency command)
1: H (output frequency)
2: U (multi-function display, see Pr. 00-04)
3: A (output current)
0: Display output current (A) (Unit: Amp)
1: Display counter value (c) (Unit: CNT)
2: Display actual output frequency (H.) (Unit: Hz)
3: Display DC BUS voltage (v) (Unit: V
4: Display output voltage (E) (Unit: V
5: Display output power angle (n) (Unit: deg)
6: Display output power in kW (P) (Unit: kW)
7: Display actual motor speed rpm (r) (Unit: rpm)
8: Display estimate output torque % (t) (Unit: %)
9: Display PG feedback (G) (refer to Pr. 10-00 and
Pr. 10-01) (Unit: PLS)
10: Display PID feedback (b) (Unit: %)
11: Display AVI in % (1.) (Unit: %)
12: Display ACI in % (2.) (Unit: %)
13: Display AUI in % (3.) (Unit: %)
14: Display the temperature of IGBT (i.) (Unit: °C)
15: Display the temperature of capacitance (c.)
(Unit: °C)
16: The status of digital input (ON / OFF) (i)
17: The status of digital output (ON / OFF) (o)
18: Multi-step speed (S)
19: The corresponding CPU pin status of digital
input (d)
20: The corresponding CPU pin status of digital
output (0.)
21: Actual motor position (PG1 of PG card) (P.)
The maximum value is 32bits display
22: Pulse input frequency (PG2 of PG card) (S.)
23: Pulse input position (PG2 of PG card) (q.)
The maximum value is 32bits display
11-3
Default
0
)
DC
)
AC
3