Descriptions Of Digital Keypad - Delta C2000 Plus Series User Manual

High performance vector control drive
Table of Contents

Advertisement

Chapter 10 Digital KeypadC2000 Plus

10-1 Descriptions of Digital Keypad

KPC-CC01
Keypad Function Description
Key
Start Operation Key
1. Only valid when the source of operation command is the keypad.
2. Operates the AC motor drive by the function setting. The RUN LED will be ON.
3. Can be pressed repeatedly at the stop process.
Stop Command Key.
1. This key has the highest priority when the command is from the keypad.
2. When it receives the STOP command, regarless of whether the AC motor drive is in
operation or stop status, the AC motor drive executes the "STOP" command.
3. Use the RESET key to reset the drive after a fault occurs.
4. If you cannot reset after the error:
a. The condition which triggers the fault is not cleared. After you clear the condition, you can
b. The drive is in fault status when powered on. After you clear the condition, restart and
Operation Direction Key
1. Only controls the operation direction, NOT the drive activation. FWD: forward, REV: reverse.
2. Refer to the LED descriptions for more details.
ENTER Key
Goes to the next menu level. If at the last level, press ENTER to execute the command.
ESC Key
Leaves the current menu and returns to the previous menu; also functions as a return key or
cancel key in a sub-menu.
Returns to the main menu.
Menu commands:
1. Parameter Setup
2. Quick Start
3. Application Selection List
4. Changed List
5. Copy Parameter
6. Fault Record
Direction: Left / Right / Up / Down
1. In the numeric value setting mode, moves the cursor and changes the numeric value.
2. In the menu / text selection mode, selects an item.
Communication Interface
RJ45 (socket), RS-485 interface
Communication protocol:
RTU19200, 8, N, 2
Installation Method
1. The embedded type can be installed flat on the surface of the control box. The
front cover is waterproof.
2. Buy a MKC-KPPK model for wall mounting or embedded mounting. Its
protection level is IP66.
3. The maximum RJ45 extension lead is 5 m (16ft).
4. This keypad can only be used on Delta's motor drive C2000 series, CH2000
and CP2000 series.
then reset the fault.
then you can reset the fault.
Descriptions
7. Language Setup
8. Time Setup
9. Keypad Locked
10. PLC Function
11. Copy PLC
12. Display Setup
10-2
13. Start-up Menu
14. Main Page
15. PC Link
16. Start Wizard

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vfd007c23a-21Vfd007c43a-21Vfd007c4ea-21Vfd015c23a-21Vfd015c43a-21Vfd015c4ea-21 ... Show all

Table of Contents