Motor Zero-speed Level
Settings
 This parameter should be used with the multi-function output terminals (set to 43). It needs to be
used with PG card and motor with encoder feedback.
 Use this parameter to set the level of motor at zero-speed. When the speed is lower than this
setting, the corresponding multi-function output terminal that is set to 43 is ON, as shown below:
Maximum Frequency of Resolution Switch
Settings
Switch delay time of Maximum output frequency
Settings
 Use to improve unstable speed or unstable position due to insufficient analog resolution. Use with
the external terminal (setting to 43). After setting this parameter, you also need to adjust the
analog output resolution of the controller so as to work with the parameter function.
0~65535 rpm
0.00~599.00Hz
0~65.000 sec.
12.1-02-23
Chapter 12 Description of Parameter SettingsC2000
Default: 0
Default: 60.00
Default: 0.000