Chapter 9 Specification C2000
Frame Size
Model VFD-_ _ _ C_ _
Rated Output Capacity [kVA]
Rated Output Current [A]
Applicable Motor Output [kW]
Applicable Motor Output [HP]
Overload Capacity
Max. Output Frequency [Hz]
Carrier Frequency [kHz]
Rated Output Capacity [kVA]
Rated Output Current [A]
Applicable Motor Output [kW]
Applicable Motor Output [HP]
Overload Capacity
Max. Output Frequency [Hz]
Carrier Frequency [kHz]
Normal Duty
Input Current [A]
Heavy Duty
Rated Voltage / Frequency
Operating Voltage Range
Frequency Tolerance
Efficiency [%]
Power Factor
Drive Weight [Kg]
Cooling Method
Braking Chopper
DC choke
EMC Filter
EMC-COP01
NOTE
*
1.
: The factory setting is Normal Duty mode.
2. The carrier frequency is default. Increasing the carrier frequency requires a reduction in current. Please refer to Chapter 9-7
Derating Curve of Ambient Temperature.
3. The AC motor drive should operate in derating current when its control method is set to FOC Sensorless, TQC+PG, TQC
sensorless. PM+PG, PM sensorless Please refer to Pr. 06-55 for more information.
4. Select the AC motor drive with capacity one grade larger for the impact load application.
5. The rated input current will be affected by not only Power Transformer and the connection of the reactors on input side, but
also fluctuates with the impedance of power side.
6. For Frame A, B and C, Model VFDXXXC43A is under IP20/NEMA1/UL TYPE1 protection level.
7. For Frame D and above, if the last character of the model is A then it is under IP20 protection level but the wiring terminal is
under IP00 protection level; if the last character of the model is E, it is under IP20/NEMA1/UL TYPE1 protection level.
8. Model VFD4500C43x does not have UL certification.
D0
D
370
450
550
750
900
58
73
88
120
143
73
91
110
150
180
37
45
55
75
90
50
60
75
100
125
120% of rated output current: 1 minute for every 5 minutes;
160% of rated output current: 3 seconds for every 30 seconds
2~10 (Default: 6)
55
69
84
114
136
69
86
105
143
171
30
37
45
55
75
40
53
60
75
100
150% of rated output current: 1 minute for every 5 minutes;
180% of rated output current: 3 seconds for every 30 seconds
2~10 (Default: 2)
74
101
114
157
167
70
96
108
149
159
3-phase AC 380V~480V (-15% +10%), 50 / 60Hz
97.8
27 ± 1.5
38.5 ± 1.5
64.8 ± 1.5
VFDXXXC43A:Optional; VFDXXXC43E: Built-in
9-4
E
F
1100
1320
1600
1850
175
207
247
295
220
260
310
370
110
132
160
185
150
175
215
250
0.00~599.00
2~9 (Default: 4)
167
197
235
280
209
247
295
352
90
110
132
160
125
150
175
215
0.00~300.00
2~9 (Default: 2)
207
240
300
380
197
228
285
361
323~528V
AC
47~63Hz
98.2
>0.98
86.5 ± 1.5
134 ± 4
Fan cooling
Frame D0~H: Optional
Frame D0~H: Built-in
Frame D0~H: Optional
G
H
2200
2800
3150
3550
367
438
491
544
460
550
616
683
220
280
315
355
300
375
420
475
348
417
466
517
437
523
585
649
185
220
280
315
250
300
375
425
400
494
555
625
380
469
527
594
228
Table 9-3
4500
720
866
450
600
677
815
355
475
866
815