Delta C2000 Series User Manual page 111

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 7 Optional AccessoriesC2000
Applicable
Motor (kW)
Braking
LD
ND HD
Torque
[kg-m]
450 355 315
240.3
560 450 355
304.7
630 630 630
426.5
Calculation for 125% brake toque: (kW) * 125% * 0.8; where 0.8 is motor efficiency.
*1.
Because of the limited resistor power, the longest operation time for 10% ED is 10 seconds (on: 10 seconds / off: 90 seconds).
*2.
Refer to Chapter 7 "Brake Module and Brake Resistors" in application manual for "Operation Duration & ED" vs. "Braking
Current".
*3.
For heat dissipation, a resistor of 400W or lower should be fixed to the frame and maintain the surface temperature below
250°C; a resistor of 1000W and above should maintain the surface temperature below 350°C.
*4.
Please refer to VFDB series Braking Module Instruction for more detail on braking resistor.
NOTE
1.
Specification and appearance of brake resistors
1-1 Wirewound resistor: for 1000W and above. Refer to the following appearance of wirewound resistor
(Figure7-1) and its model and specification comparison table (Table 7-5) for details.
K
1
125% Braking Torque / 10%ED
Brake
Braking Resistor series for
3
Unit
each Brake Unit
VFDB
6200*2
BR1K5W027*14
6200*3
BR1K5W027*12
6200*4
BR1K5W027*12
H
L
Resistor value
spec. for each
AC motor drive
2 series,
42000W 3.9Ω
7 parallel
2 series,
54000W 3.0Ω
6 parallel
2 series,
72000W 2.3Ω
6 parallel
E
A
B
7-4
2
Max. Braking Torque
Max.
Total
Min.
Total
Braking
Resistor
Braking
Current
Value
Current
[A]
[Ω]
[A]
290.4
3.5
324
373.3
2.3
486
497.8
1.7
648
Table 7-4
Figure 7-1
Table 7-5
Peak
Power
[kW]
362.9
544.3
725.8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents