Delta C2000 Series User Manual page 351

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 11 Summary of Parameter SettingsC2000
Pr.
Parameter Name
02-13
Multi-function output 1 RLY1
02-14
Multi-function output 2 RLY2
02-16
Multi-function output 3 (MO1)
02-17
Multi-function output 4 (MO2)
Output terminal of the I/O extension
02-36
card (MO10) or (RA10)
Output terminal of I/O extension card
02-37
(MO11) or (RA11)
Output terminal of I/O extension card
02-38
(RA12)
Output terminal of I/O extension card
02-39
(RA13)
Output terminal of I/O extension card
02-40
(RA14)
Output terminal of I/O extension card
02-41
(RA15)
Output terminal of I/O extension card
02-42
(MO16 virtual terminal)
Output terminal of I/O extension card
02-43
(MO17 virtual terminal)
Output terminal of I/O extension card
02-44
(MO18 virtual terminal)
Output terminal of I/O extension card
02-45
(MO19 virtual terminal)
Output terminal of I/O extension card
02-46
(MO20 virtual terminal)
Setting Range
0: No function
1: Indication during RUN
2: Operation speed reached
3: Desired frequency reached 1 (Pr. 02-22)
4: Desired frequency reached 2 (Pr. 02-24)
5: Zero speed (Frequency command)
6: Zero speed including STOP (Frequency
command)
7: Over-torque 1 (Pr. 06-06–06-08)
8: Over-torque 2 (Pr. 06-09–06-11)
9: Drive is ready
10: Low voltage warning (Lv) (Pr. 06-00)
11: Malfunction indication
12: Mechanical brake release (Pr. 02-32)
13: Over-heat warning (Pr. 06-15)
14: Software brake signal indication (Pr. 07-00)
15: PID feedback error (Pr. 08-13, Pr. 08-14)
16: Slip error (oSL)
17: Count value reached, does not return to 0
(Pr. 02-20)
18: Count value reached, returns to 0
(Pr. 02-19)
19: External interrupt B.B. input (Base Block)
20: Warning output
21: Over-voltage
22: Over-current stall prevention
23: Over-voltage stall prevention
24: Operation mode
25: Forward command
26: Reverse command
27: Output when current ≥ Pr. 02-33
28: Output when current < Pr. 02-33
29: Output when frequency ≥ Pr. 02-34
30: Output when frequency < Pr. 02-34
31: Y-connection for the motor coil
32:
-connection for the motor coil
33: Zero speed (actual output frequency)
34: Zero speed including stop (actual output
frequency)
35: Error output selection 1 (Pr. 06-23)
11-16
Default
11
1
66
0
0
0
0
0
0
0
0
0
0
0
0

Hide quick links: