Delta C2000 Series User Manual page 806

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Command
Drive coil
OUT
X0–X17
Operand
Outputs result of logical operation before OUT command to the designated element.
Coil contact action:
Result:
FALSE
TRUE
Ladder diagram:
X0
Command
Action continues (ON)
SET
X0–X17
Operand
When the SET command is driven, the designated element will be set as On, and will
be maintained in an On state, regardless of whether the SET command is still driven.
The RST command can be used to set the element as Off.
Ladder diagram:
X0
Command
Clear contact or register
RST
X0–X17
Operand
When the RST command is driven, the action of the designated element will be as
follows:
Element
Y, M
Both coil and contact will be set as Off.
The current timing or count value will be set as 0, and both the coil
T, C
and contact will be set as Off.
D
The content value will be set as 0.
If the RST command has not been executed, the status of the designated element will
remain unchanged.
Ladder diagram:
X0
Y0–Y17
M0–M799
Out command
Coil
Contact a (NO)
Off
Not conducting
On
Conducting
X1
Y1
Y0–Y17
M0–M799
Y0
Y1
SET
Y0–Y17
M0–M799
Y5
RST
16-45
Chapter 16 PLC Function ApplicationsC2000
Function
T0–159
Access Point:
Contact b (NC)
Conducting
Not conducting
Command code:
LD
X0
AND
X1
OUT
Y1
Function
T0–159
Command code:
LD
X0
AN
Y0
SET
Y1
Function
T0–159
Mode
Command code:
LD
X0
RST
Y5
C0–C79
D0–D399
Description:
Load Contact b of X0
Establish parallel
connection to contact a
of X1
Drive Y1 coil
C0–C79
D0–D399
Description:
Load Contact a of X0
Establish parallel
connection to contact b
of Y0
Action continues (ON)
C0–C79
D0–D399
Description:
Load Contact a of X0
Clear contact or
register

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents