Delta C2000 Series User Manual page 696

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

ID*
Display on LCM Keypad
34
Action level
Action time
Fault treatment parameter
Reset method
Reset condition
Record
Cause
Hardware failure
ID*
Display on LCM Keypad
35
Action level
Action time
Fault treatment parameter
Reset method
Reset condition
Record
Cause
Hardware failure
ID*
Display on LCM Keypad
36
Action level
Action time
Fault treatment parameter
Reset method
Reset condition
Record
Cause
Hardware failure
Fault Name
V-phase error (cd2)
V-phase current detection error when power ON
Action and Reset
Hardware detection
cd2 acts immediately when the drive detects the fault
N/A
Power-off
N/A
Yes
Cycle the power.
If cd2 still exists, return to the factory for repair.
Fault Name
W-phase error
W-phase current detection error when power ON
(cd3)
Action and Reset
Hardware detection
cd3 acts immediately when the drive detects the fault
N/A
Power-off
N/A
Yes
Cycle the power.
If cd3 still exists, return to the factory for repair.
Fault Name
cc hardware failure
cc (current clamp) hardware protection error when
(Hd0)
power is ON
Action and Reset
Hardware detection
Hd0 acts immediately when the drive detects the fault
N/A
Power-off
N/A
Yes
Cycle the power.
If Hd0 still exists, return to the factory for repair.
14-25
Chapter 14 Fault Codes and DescriptionsC2000
Fault Descriptions
Corrective Actions
Fault Descriptions
Corrective Actions
Fault Descriptions
Corrective Actions

Hide quick links:

Advertisement

Table of Contents
loading