Delta C2000 Series User Manual page 809

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 16 PLC Function ApplicationsC2000
Command
Forward edge detection series connection
ANDP
X0–X17
Operand
The ANDP command used for a contact rising edge detection series connection.
Ladder diagram:
X0
Command
Reverse edge detection series connection
ANDF
X0–X17
Operand
The ANDF command is used for a contact falling edge detection series connection.
Ladder diagram:
X0
Command
Forward edge detection parallel connection
ORP
X0–X17
Operand
The ORP command is used for a contact rising edge detection parallel connection.
Ladder diagram:
Command
Reverse edge detection parallel connection
ORF
X0–X17
Operand
The ORF command is used for contact falling edge detection parallel connection.
Ladder diagram:
Y0–Y17
X1
Y1
Y0–Y17
X1
Y1
Y0–Y17
X0
X1
Y0–Y17
X0
X1
Function
M0–M799
T0–159
Command code:
LD
ANDP
OUT
Function
M0–M799
T0–159
Command code:
LD
ANDF
OUT
Function
M0–M799
T0–159
Command code:
Y1
LD
ORP
OUT
Function
M0–M799
T0–159
Command code:
LD
Y1
ORF
OUT
16-48
C0–C79
D0–D399
Description:
X0
Load Contact a of X0
X1 Forward edge
detection series
X1
connection
Y1
Drive Y1 coil
C0–C79
D0–D399
Description:
X0
Load Contact a of X0
X1 Reverse edge
detection series
X1
connection
Y1
Drive Y1 coil
C0–C79
D0–D399
Description:
X0
Load Contact a of X0
X1 Forward edge
detection parallel
X1
connection
Y1
Drive Y1 coil
C0–C79
D0–D399
Description:
X0
Load Contact a of X0
X1 Reverse edge
detection parallel
X1
connection
Y1
Drive Y1 coil

Hide quick links: