Delta C2000 Series User Manual page 95

Vector control drive
Hide thumbs Also See for C2000 Series:
Table of Contents

Advertisement

Chapter 5 Main Circuit TerminalsC2000
Frame G
R/L11
R/L12
S/L21
S/L22
If you install at Ta 50
°C
63B-00) / 40
(for 230V / 460V model names with last digit A; for 690V model names end with 63B-21)
environment, please select copper wire with voltage rating 600V and temperature resistant at 75
If you install at Ta 50
°C
63B-00) / 40
(for 230V / 460V model names with last digit A; for 690V model names end with 63B-21)
above environment, please select copper wire with voltage rating 600V and temperature resistant at 90
above.
For VFD2200C43A, if you install at Ta 45
rating 600V and temperature resistant at 90
For UL installation compliant, please use copper wires for installation, the wire gauge is based on
temperature resistant at 75
when using higher temperature wire.
R/L11, R/L12, S/L21, S/L22, T/L31, T/L32
Model Name
Max. Wire
Gauge
VFD1850C43A
VFD2200C43A
120mm
[250MCM*4]
VFD1850C43E
VFD2200C43E
VFD2500C63B-00
VFD3150C63B-00
150mm
[300MCM*4]
VFD2500C63B-21
VFD3150C63B-21
Model Name
Max. Wire
Gauge
VFD1850C43A
VFD2200C43A
VFD1850C43E
VFD2200C43E
240mm
[500MCM*2]
VFD2500C63B-00
VFD3150C63B-00
VFD2500C63B-21
VFD3150C63B-21
T/L31
T/L32
+1/DC
-/DC-
°C
(for 230V / 460V model names with last digit A; for 690V model names end with
°C
(for 230V / 460V model names with last digit A; for 690V model names end with
°C
above environment, please select copper wire with voltage
°C
°C
which is requested and recommended from UL. Do not reduce the wire gauge
Main Circuit Terminals
Min. Wire Gauge
70 mm
2
*4 [2/0AWG*4]
95 mm
2
*4 [3/0AWG*4]
2
*4
50 mm
*4 [1/0AWG*4]
2
70 mm
2
*4 [2/0AWG*4]
2
*4
50 mm
2
*4 [1/0 AWG*4]
Main Circuit Terminals
U/T1, V/T2, W/T3, +1/DC+, -/DC-
Min. Wire Gauge
240 mm
2
*2 [400MCM*2]
240 mm
2
*2 [500MCM*2]
150 mm
2
*2 [300MCM*2]
240 mm
2
*2 [400MCM*2]
2
*2
120 mm
2
*2 [250MCM*2]
150 mm
2
*2 [350MCM*2]
120 mm
2
*2 [250MCM*2]
150 mm
2
*2 [350MCM*2]
U/T1
V/T2
W/T3
or above.
Screw Spec.
Max. Wire
and Torque
Gauge
(±10%)
70 mm
2
*4
[2/0AWG*4]
95 mm
2
*4
[3/0AWG*4]
50 mm
2
*4
M8
[1/0AWG*4]
180kg-cm
70 mm
*4
2
[156.2 lb-in.]
[2/0AWG*4]
[17.65Nm]
50 mm
2*
4
[1/0 AWG*4]
Screw Spec.
Max. Wire
and Torque
Gauge
(±10%)
240 mm
2
*2
[400MCM*2]
240 mm
2
*2
[500MCM*2]
150 mm
2
*2
[300MCM*2]
240 mm
2
*2
M12
[400MCM*2]
408kg-cm
[354.1 lb-in.]
120 mm
*2
2
[39.98 Nm]
[250MCM*2]
150 mm
2
*2
[350MCM*2]
120 mm
2
*2
[250MCM*2]
150 mm
2
*2
[350MCM*2]
5-16
°C
Terminal
Screw Spec.
and Torque
Min. Wire Gauge
70 mm
2
*2 [2/0AWG*2]
95 mm
2
*2 [3/0AWG*2]
50 mm
*2 [1/0AWG*2]
2
180kg-cm
70 mm
2
*2 [2/0AWG*2]
[156.2 lb-in.]
[17.65Nm]
50 mm
2*
2 [1/0 AWG*2]
Terminal
Screw Spec.
and Torque
Min. Wire Gauge
240 mm
2
*1 [400MCM*1]
240 mm
2
*1[500MCM*1]
150 mm
2
*1 [300MCM*2]
240 mm
2
*1 [400MCM*1]
180kg-cm
[156.2 lb-in.]
120 mm
2*
1 [250MCM*1]
[17.65Nm]
150 mm
2
*1 [350MCM*1]
120 mm
2
*1 [250MCM*1]
150 mm
2
*1 [350MCM*1]
°C
or 90
.
°C
or
(±10%)
M8
(±10%)
M8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents