Executing Restart Search (Restart Type 1) - Mitsubishi Electric 700 Series Training Manual

Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

2. Monitor Screens

2.3.2 Executing Restart Search (Restart Type 1)

When feed hold has been applied and reset because the tool has broken, etc., restart with Restart type 1.
Operation method
(Example) When tool breakage during execution of O1000 N7 occurred, and restarting from the O1000 N6
block.
(1) Press the feed hold button and retreat to
the tool change position by manual means
or MDI.
Press the reset key and suspend the
present processing.
(2) Replace with a new tool.
(3) When using tape operation, index the top
of the tape.
(4) Press the main menu Resrart .
(5) Set the position to restart search in the
setting area.
(6) Press the INPUT or Search exec
menu.
The submenu appears.
The main screen for restart search appears as a pop-up
window.
Delimit the ONB number in the setting area using /.
<When O No. was attached>
The main or sub program is targeted.
(Ex.) 1000/6/0
<When O No. was not attached>
The program currently searched is targeted.
(Ex.) /6/0
(Note) When the INPUT key is pressed without entering data
in the input area, restart search will be carried out for
the last execution block. (Type 1 only)
Restart search is executed.
The message "In restart search" appears during the search
process, and the message "Restart search complete"
appears when completed.
Each axis' restart position and the restart remaining distance
are displayed.
When the MSTB history menu is pressed, the MSTB
history screen will open as a pop-up window, and the M, S, T,
B command used in the machining program will be listed.
31
2.3 Restart Search

Advertisement

Table of Contents
loading

This manual is also suitable for:

70 series

Table of Contents