D-Link DXS-3600 Series Cli Reference Manual page 429

Layer 2/3 managed 10gigabit
Hide thumbs Also See for DXS-3600 Series:
Table of Contents

Advertisement

DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
Command Default Level
Level: 12.
Usage Guideline
This command is available for the physical port interface configuration.
A user can use this command to enable or disable optical transceiver monitoring functions for an
SFP/SFP+/QSFP+ port. When the monitoring function is enabled, an alarm event occurs when the
parameters being monitored go higher than the high alarm threshold or go lower than the low alarm
threshold. A warning event occurs when the parameters being monitored go higher than the high warning
threshold or go lower than the low warning threshold.
When an SFP/SFP+/QSFP+ with transceiver monitoring capability is plugged into a port but the
transceiver monitoring function of the port is disabled, the system will not detect the SFP/SFP+/QSFP+
transceiver's abnormal status but the user can still check the current status by showing the interface
transceiver command.
Example
This example shows how to enable transceiver monitoring on interface Ethernet 1/0/1.
Switch# configure terminal
Switch(config)# interface ethernet 1/0/1
Switch(config-if)# transceiver-monitoring enable
Switch(config-if)#
29-6 transceiver-monitoring rx-power
This command is used to configure the thresholds of the input power for the specified port. Use the no
form of the command to remove the configuration.
transceiver-monitoring rx-power INTERFACE-ID {high | low} {alarm | warning} {mwatt VALUE |
dbm VALUE}
no transceiver-monitoring rx-power INTERFACE-ID {high | low} {alarm | warning}
Parameters
INTERFACE ID
high
low
alarm
warning
mwatt VALUE
dbm VALUE
Default
None.
Command Mode
Specifies the interface to modify.
Specifies that when the operating parameter rises above the highest
threshold, it indicates an abnormal status
Specifies that when the operating parameter falls below the low
threshold this value, it indicates an abnormal status.
Specifies to configure the high and low threshold value condition.
Specifies to configure the high and low warning threshold conditions.
Specifies the power threshold value in milliwatts. This value must be
between 0 and 6.5535.
Specifies the power threshold value in dBm. This value must be
between -40 and 8.1647.