D-Link DXS-3600 Series Cli Reference Manual page 425

Layer 2/3 managed 10gigabit
Hide thumbs Also See for DXS-3600 Series:
Table of Contents

Advertisement

DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
eth1/0/49
30.090
Channel 1
Channel 2
Channel 3
Channel 4
eth1/0/50
30.090
eth1/0/51
30.090
eth1/0/52
30.090
eth1/0/53
30.090
Switch#
This example shows how to display detailed transceiver monitoring information for all ports which are
valid for transceiver monitoring.
Switch# show interfaces transceiver detail
++ : high alarm, +
: high warning, -
mA: milliamperes, mW: milliwatts
A: The threshold is administratively configured.
eth1/0/28
Transceiver Monitoring is enabled
Transceiver Monitoring shutdown action:Alarm
Current
Temperature(C)
30.090
Voltage (v)
3.353
Bias Current(mA) 16.794(++)
TX Power (mW)
0.258
(dbm)
-5.900
RX Power (mW)
0.000(--)
(dbm)
-(--)
eth1/1/1
Transceiver Monitoring is enabled
Transceiver Monitoring shutdown action: Alarm
Current
Temperature(C)
30.090
Voltage (v)
3.353
Bias Current(mA)
channel 1
16.794(++)
channel 2
16.794(++)
channel 3
16.794(++)
3.353
16.794(++)
16.794(++)
16.794(++)
16.794(++)
3.353
16.794(++)
3.353
16.794(++)
3.353
16.794(++)
3.353
16.794(++)
: low warning, -- : low alarm
High-Alarm High-Warning Low-Warning
75.000(A)
70.000
3.630
3.465
10.500
9.000
1.413
0.708
1.500
-1.500
1.585
0.794
2.000
-1.000
High-Alarm High-Warning Low-Warning
75.000(A)
70.000
3.630
3.465
10.500
9.000
420
-5.900
-(--)
0.000
-(--)
0.000
-(--)
0.000
-(--)
0.000
-(--)
0.000
-(--)
0.000
-(--)
0.000
-(--)
0.000
-(--)
Low-Alarm
0.000
-5.000
3.135
2.970
2.500
2.000
0.186
0.074
-7.300
-11.300
0.102
0.041
-9.900
-13.900
Low-Alarm
0.000
3.135
2.500
-5.000
2.970
2.000

Advertisement

Table of Contents
loading

Table of Contents