DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
alarm
warning
Default
By default, this option is disabled.
Command Mode
Interface Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
This command is available for physical port interface configuration.
The configuration can select to shut down a port on an alarm event or warning event or not to shut down
on either of them. When the monitoring function is enabled, an alarm event occurs when the parameters,
being monitored, go higher than the high alarm threshold or go lower than the low alarm threshold. A
warning event occurs when the parameters being monitored go higher than the high warning threshold or
go lower than the low warning threshold.
The port shutdown feature is controlled by the Error Disable module without a recover timer. Users can
manually recover the port by using the shutdown command and then the no shutdown command.
Example
This example shows how to configure the shutdown interface Ethernet 1/0/1 when an alarm event is
detected.
Switch# configure terminal
Switch(config)# interface ethernet 1/0/1
Switch(config-if)# transceiver-monitoring action shutdown alarm
Switch(config-if)#
29-4 transceiver-monitoring bias-current
This command is used to configure the thresholds of the bias current for a specified port.
Use the no form of the command to remove the configuration.
transceiver-monitoring bias-current INTERFACE-ID {high | low} {alarm | warning} VALUE
no transceiver-monitoring bias-current INTERFACE-ID {high | low} {alarm | warning}
Parameters
INTERFACE-ID
high
low
alarm
warning
VALUE
Specifies to shut down a port when alarm events occur.
Specifies to shut down a port when warning events occur.
Specifies the interface to modify.
Specifies the high threshold, when the operating parameter rises
above this value. It indicates an abnormal status.
Specifies the low threshold, when the operating parameter falls below
this value, It indicates an abnormal status.
Specifies the threshold for high alarm or low alarm conditions.
Specifies the threshold for high warning or low warning conditions.
Specifies the value of the threshold. This value must be between 0 and
131 mA.