Comtech EF Data CDM-425 Installation And Operation Manual page 536

Advanced satellite modem (18 kbps – 25 mbps)
Table of Contents

Advertisement

10.4.2.4.2.1 ODU | Config (CSAT-5060)
Figure 10-10 shows the 'ODU | Config' page as it appears with you configure the Comtech EF
Data CSAT-5060 as the ODU. Use this page to configure the primary ODU's Transmit and
Receive Parameters.
ODU Selection
If you use ODUs in redundancy, you may toggle this page between the Online and Offline units.
Use the drop-down list to select CSAT #1 or CSAT #2, and then click [Select ODU]. A message
in the right hand column of this section identifies which unit is 'ONLINE'.
Up Converter Parameters
Frequency – Enter a value in MHz.
Attenuation – Enter a value in dB.
Slope Mode – From the drop-down list, select Manual or Calibrated.
Slope Adjust (Manual Mode Only) – Select the desired setting from the drop-down list.
Mute – From the drop-down list, select Disable or Enable.
Gain Offset (1:1 Redundancy Only) – Select the desired setting from the drop-down
list.
Amplifier – From the drop-down list, select On or Off.
ODU (Transceiver, BUC, LNB) Operation
Figure 10-10. ODU | Config Page (CSAT-5060)
10–46
CDM-425 Advanced Satellite Modem
MN-CDM-425
Revision 0