Use the ◄ ►arrow keys to select a setting, and then use the ▲▼ arrow keys to edit the setting:
Selection
AFR
Ref-Adjust
LowFwdPower
Threshold
Sync-Clock
Press ENTER when done.
10.3.3.3.3.4.3.1.2 ODU: FSK-control  BUC  Advanced-FSK  LPOD (2LPODs  Online/Offline LPOD)
Monitor
Monitor: Tx
Power-Supplies1 Power-Supplies2
To view these read-only LPOD Monitor screens, use the ▲▼ arrow keys to select Tx, Temp,
FETs, Misc, or Power-Supplies, and then press ENTER.
Once any of these screens are viewed, press ENTER or CLEAR to return to the previous menu.
ODU: FSK-control  BUC  Advanced-FSK  LPOD (2LPODs 
Online/Offline LPOD)  Monitor Tx
Tx: RefTune=009.6 V FwdPower = +20.4 dBm
ODU (Transceiver, BUC, LNB) Operation
(Auto Fault Recovery) This defines how a LPOD reacts to momentary fault conditions:
Disable – LPOD mutes when faulted and remain muted.
Enable – LPOD mutes when faulted, and then unmutes once the fault goes away.
Select an Internal 10MHz Reference setting from 000 to 255.
NOTE: The Internal Reference is set in the factory to be very accurate with the default setting
of 087. This setting is provided to compensate for the long-term frequency drift of the
oscillator.
This sets the threshold for the low forward power alarm/fault. An alarm/fault is triggered if the
forward power drops below the specified value. Set this setting to 00.00 to disable the
threshold.
Select YES and press ENTER to synchronize the LPOD RTC to the Modem RTC. (Default is
NO.)
Temperature
BUCTune=011.1 V
CDM-425 Advanced Satellite Modem
Setting
FET
Misc
10–30
Revision 0
()
MN-CDM-425

Advertisement

Table of Contents
loading