15.1.5.2

Pulse Width Modules

750-511, (and all variations /xxx-xxx)
The above Pulse Width modules have a total of 6 bytes of user data in both the
Input and Output Process Image (4 bytes of channel data and 2 bytes of control/
status). The two channel values are supplied as 16 bits. Each channel has its own
control/status byte. The following table illustrates the Input and Output Process
Image, which has a total of 4 words mapped into each image. Word alignment is
applied.

Table 288: Pulse Width Modules 750-511, /xxx-xxx

Input and Output Process
Offset
0
1
2
3
15.1.5.3

Serial Interface Modules with alternative Data Format

750-650, (and the variations /000-002, -004, -006, -009, -010, -011, -012, -013),
750-651, (and the variations /000-001, -002, -003),
750-653, (and the variations /000-002, -007),
753-650, -653
The process image of the / 003-000-variants depends on the parameterized
operating mode!
With the freely parameterizable variations /003 000 of the serial interface
modules, the desired operation mode can be set. Dependent on it, the process
image of these modules is then the same, as from the appropriate variation.
The above Serial Interface Modules with alternative data format have a total of 4
bytes of user data in both the Input and Output Process Image (3 bytes of serial
data and 1 byte of control/status). The following table illustrates the Input and
Output Process Image, which have a total of 2 words mapped into each image.
Word alignment is applied.

Table 289: Serial Interface Modules with alternative Data Format

Input and Output Process Image
Offset
0
1
Byte Destination
High Byte
-
D1
-
D3
Byte Destination
High Byte
D0
D2
750-8208 PFC200 CS 2ETH RS CAN DPM
Low Byte
C0/S0
Control/Status byte of Channel 1
D0
C1/S1
Control/Status byte of Channel 2
D2
Low Byte
C/S
D1
Version 1.1.0, valid from FW Version 02.06.20(09)
WAGO-I/O-SYSTEM 750
Description
Data Value of Channel 1
Data Value of Channel 2
Description
Control/status
Data byte
byte
Data bytes
Manual