WAGO-I/O-SYSTEM 750
750-8208 PFC200 CS 2ETH RS CAN DPM
10.4.1.4

Performing Subscriber Diagnostics using DiagGetState()

If the bus diagnostics have revealed that an I/O module contains diagnostic
information, then perform participant diagnostics on the corresponding slave.
Proceed as follows:
1.
Call up the function block DiagGetState() by setting the input ENABLE to
"True."
2.
Specify the slave that provides the diagnostic information at the input
variable BUSMEMBERID. In this example, it is the slave with the fieldbus
address 5.

Figure 136: DiagGetState() Diagnostic Call

DRIVERNAME:
The input parameter DRIVERNAME is specified through the instance data
of the function block DiagGetBusState.
DEVICENUMBER:
The DEVICENUMBER is device-specific and the variable
"DeviceNumber" must be adapted accordingly based on the information
given in the Section "Appendix" > ... > "BusDiag.lib".
Manual
Version 1.1.0, valid from FW Version 02.06.20(09)
CANopen Master and Slave