System Events; Figure 82: Debugging (Case 7) - WAGO I/O SYSTEM 750 Manual

750-8208 pfc200 cs 2eth rs can dpm plc - controller pfc200
Hide thumbs Also See for I/O SYSTEM 750:
Table of Contents

Advertisement

WAGO-I/O-SYSTEM 750
750-8208 PFC200 CS 2ETH RS CAN DPM
If a task is at a breakpoint and the connection to the IDE is broken (e.g., by
logging out), all breakpoints are deleted.
The debug task stays at the current position until the next time the mode selector
switch is switched from STOP to RUN. In this case, the task continues to run
from the current position (case 7).

Figure 82: Debugging (Case 7)

8.5

System Events

Event tasks can be used in the CODESYS task configuration in addition to
cyclical tasks. Event tasks call up certain events in the device.
To activate events and define a program to be called up, open the window "Task
configuration" in the "Resources" tab in the CODESYS development
environment.
Manual
Version 1.1.0, valid from FW Version 02.06.20(09)
Run-time System CODESYS 2.3
231