4 Faults and alarms
4.2 List of faults and alarms
A36217 (N)
Hub: undervoltage alarm 24 V supply
Message value:
%1
Message class:
Supply voltage fault (undervoltage) (3)
Drive object:
B_INF, HUB, VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
The 24 V power supply on the DRIVE-CLiQ Hub Module has undershot the alarm threshold.
Alarm value (r2124, interpret decimal):
Actual operating voltage in 0.1 °C resolution
Remedy:
- check the supply voltage of the component involved.
- replace the component involved.
Reaction upon N:
NONE
Acknowl. upon N:
NONE
N36800 (F)
Hub: Group signal
Message value:
-
Message class:
General drive fault (19)
Drive object:
B_INF, HUB, VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
The DRIVE-CLiQ Hub Module has detected at least one fault.
Remedy:
Evaluates other actual messages.
Reaction upon F:
NONE
Acknowl. upon F:
IMMEDIATELY
A36801 (F, N)
Hub DRIVE-CLiQ: Sign-of-life missing
Message value:
Component number: %1, fault cause: %2
Message class:
Internal (DRIVE-CLiQ) communication error (12)
Drive object:
B_INF, HUB, VECTOR_G
Reaction:
NONE
Acknowledge:
NONE
Cause:
A DRIVE-CLiQ communications error has occurred from the Control Unit to the DRIVE-CLiQ Hub Module involved.
Fault cause:
10 (= 0A hex):
The sign-of-life bit in the receive telegram is not set.
Note regarding the message value:
The individual information is coded as follows in the message value (r0949/r2124):
0000yyxx hex: yy = component number, xx = error cause
Remedy:
- check the DRIVE-CLiQ connection.
- replace the component involved.
See also: p9916 (DRIVE-CLiQ data transfer error shutdown threshold slave)
Reaction upon F:
NONE
Acknowl. upon F:
IMMEDIATELY
Reaction upon N:
NONE
Acknowl. upon N:
NONE
F36802 (N, A)
Hub: Time slice overflow
Message value:
%1
Message class:
Hardware / software error (1)
Drive object:
B_INF, HUB, VECTOR_G
Reaction:
Vector: NONE
Infeed: OFF2 (NONE)
Acknowledge:
IMMEDIATELY (POWER ON)
Cause:
A time slice overflow has occurred on the DRIVE-CLiQ Hub Module.
1784
SINAMICS G130/G150
List Manual (LH2), 04/2014, A5E03263479A