Adj Mode Error Message - Sony GY-8240UWD Maintenance Manual

Dtf tape drive
Table of Contents

Advertisement

5-9-9. ADJ Mode Error Message

Error Message
S reel FG error
S reel PG error
S reel FG number error
S reel FG exception error
T reel FG error
T reel PG error
T reel FG number error
T reel FG exception error
Capstan FG error
Capstan FG exception error
S tension sensor error
S tension sensor exception error
T tension sensor error
T tension sensor exception error
Auto PG error
Auto PG signal detect error
Auto PG timeout error
Auto PG exception error
S reel voltage check error
S reel voltage check exception error Unexpected state occurred such as a cassette was loaded during S reel motor
T reel voltage check error
T reel voltage check exception error
Drum jitter check error
Drum jitter check exception error
Sat check error
Sat check timeout error
Sat check Correlation error
Sat signal Over Measure Range error SAT signal exceeded measurement range
Sat check exception error
Atf check error
Atf check timeout error
Atf check correlation error
Atf Tracon error
Atf check exception error
GY-8240UWD
GY-8240FC
Details
S reel FG duty check results were unsatisfactory
S reel PG for S reel FG teeth number diagnosis not output
S reel FG teeth number was abnormal
Unexpected state occurred such as a cassette was loaded during S reel
diagnosis
T reel FG duty check results were unsatisfactory
T reel PG for T reel FG teeth number diagnosis not output
T reel FG teeth number was abnormal
Unexpected state occurred such as a cassette was loaded during T reel
diagnosis
Capstan FG check results were unsatisfactory
Unexpected state occurred such as a cassette was loaded during capstan FG
check
S tension system check results were unsatisfactory
Unexpected state occurred such as a cassette was loaded during S tension
check
T tension check results were unsatisfactory
Unexpected state occurred such as a cassette was loaded during T tension
check
Failed in PG automatic adjustment
Could not detect signals required for PG automatic adjustment
PG automatic adjustment ended in timeout
PG automatic adjustment was not possible
S reel motor terminal voltage check results were unsatisfactory
terminal voltage check
T reel motor terminal voltage check results were unsatisfactory
Unexpected state occurred such as a cassette was loaded during T reel motor
terminal voltage check
Drum jitter check results were unsatisfactory
Unexpected state occurred such as a cassette was loaded during drum jitter
check
SAT operation check error
SAT operation check ended in timeout
Abnormal relation between SAT signal and tracking control
Unexpected state occurred during SAT operation check
ATF operation check error
ATF operation check ended in timeout
Abnormal correlation of ATF signal
Tracking control value too large in servo lock state
Unexpected state occurred during ATF operation check
5-9. ADJ Mode
5-119

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gy-8240fc

Table of Contents