Sony GY-8240UWD Maintenance Manual page 379

Dtf tape drive
Table of Contents

Advertisement

Error Code
Details
1D1C3D91
T reel motor terminal voltage check results were unsatisfactory.
1D1C3D98
Unexpected state occurred such as cassette was loaded during
T reel motor terminal voltage check.
1D1C3DA1
Drum jitter check results were unsatisfactory.
1D1C3DA8
Unexpected state occurred such as cassette was loaded during
drum jitter check.
1D1C3DB1
SAT operation check error
1D1C3DB2
SAT operation check ended in timeout.
1D1C3DB3
Abnormal relation between SAT signal and tracking control
1D1C3DB4
SAT signal exceeded measurement range.
1D1C3DB8
Unexpected state occurred during SAT operation check.
1D1C3DC1
ATF operation check error
1D1C3DC2
ATF operation check ended in timeout.
1D1C3DC3
Abnormal correlation of ATF signal
1D1C3DC4
Tracking control value too large in servo lock state
1D1C3DC8
Unexpected state occurred during ATF operation check.
40000001
SIO1 communication error (PSC/Ext-dsp port)
40000002
SIO2 communication error (SV-205 port)
40000003
SIO4 communication error (Remote port)
40000004
SRAM check error
40000005
NVRAM check error
40000006
DPRAM (FMT) check error
40000007
DPRAM (SYS) check error
40000008
DPRAM (SV) check error
40000009
SDRAM check error
4000000A
Display communication error
50XXYYZZ
DSP block error
GY-8240UWD
GY-8240FC
Remedy
Check or replace T reel motor, SV-205 board.
Execute again.
Check or replace drum, SV-205 board.
Execute again.
Check cassette type.
Check or replace DPR-160 board and SV-250 board.
Or replace drum
Execute again.
Replace IF-780 board.
Replace IF-780 board.
Replace IF-780 board, harness, DSP-90 board.
Refer to "DSP error code countermeasure".
5-13. Troubleshooting
5-163