Countermeasures for SV Error Code
When errors occur in the servo block, the protection mode is set. The "protection mode" is the mode in
which the servo control block stops tape running and the drum motor automatically, and maintains the
state. When set to this protection mode, the unit cannot be recovered automatically. If the protection mode
is set with the cassette loaded, refer to "1-6. Taking out the Cassette in Tape Slacking" and be sure to
remove the cassette manually.
n
The tape may be damaged if the power is turned off and then on with the cassette loaded.
3x03
Description:
Reel shift operations uncompleted
Possible cause: . Failure of S or L position sensor (SV-205 board)
. Reel shift mechanism problems
. Failure of reel shift motor
. Failure of reel shift drive circuit (SV-205 board)
. Failure of reel shift sensor input port (SV-205 board IC902)
3x04
Description:
Cassette compartment operations uncompleted
Possible cause: . Failure of cassette compartment
. Failure of cassette compartment motor drive circuit (SV-205 board)
. Failure of cassette down sensor (CL-29 board)
. Failure of cassette down input port (SV-205 board IC902)
3x05
Description:
Threading operation uncompleted
Possible cause: . Failure of unthread sensor (TR-120 board)
. Failure of thread end sensor (TR-120 board)
. Failure of thread end/unthread end sensor input port (SV-205 board IC902)
. Failure of threading motor
. Failure of threading motor drive circuit
. Threading mechanism problem
3x06
Description:
Thread FG undetected
Possible cause: . Failure of threading motor
. Failure of threading motor FG sensor (PTC-54 board)
. Failure of threading FG amplifier (SV-205 board)
. Failure of threading motor drive circuitÇO