Sony GY-8240UWD Maintenance Manual page 302

Dtf tape drive
Table of Contents

Advertisement

5-6. LOG Mode
Time passed from power ON
Number of
Read/Write
power ON
Description of Display
Physical ID:
Longitudinal ID value supplied from SYS block
Logical ID:
Logical ID value written in sub code
ID identifier:
ID identifier written in sub code (DUMMY, EOD etc.)
C2:
Displays whether C2 occurred in Aa block, Ae block, Ea block, and Ee block.
If C2 has occurred, C2 is displayed.
CRC:
Like C2, CRC is displayed if CRC has occurred.
Envelope:
Aa0, Aa1, Bb0, Bb1. Cc0, Cc1, Dd0, and Dd1 in order from the left
C1:
C1 burst Aa, Bb, Cc, Dd, C1 random Aa, Bb, Cc, Dd in order from the left
If the physical IDs are even numbers, the first is of the Aa block, and the second is of the Ae block.
If the physical IDs are odd numbers, the first is of the Ea block, and the second is of the Ee block.
5-86
Physical ID
Logical ID ID identifier C2
ERATE (1ID) Execution Screen
CRC
Envelope
C1
GY-8240UWD
GY-8240FC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gy-8240fc

Table of Contents