Sony GY-8240UWD Maintenance Manual page 299

Dtf tape drive
Table of Contents

Advertisement

Main Routine Flag
Code
Contents
bit 0
1: Writes the EOD after transfer ends.
bit 1
1: Crush records/plays
bit 2
1: Ignores C2 errors which have occurred
bit 3
1: Inserts dummy at joined parts
bit 4
1: No auto-prerolling
bit 5
1: No C1 correction
bit 6
1: Ignores errors in disused areas
bit 7
1: Recording mode for eliminating mid part
GY-8240UWD
GY-8240FC
Interrupt Routine Flag
Code
Contents
bit 0
1: Ends transfer without continuous processing
bit 1
1: Started continuous processing
bit 2
1: Completed error check
bit 3
1: Interrupted transfer
bit 4
1: First bank of transfer
bit 5
1: READ direction
bit 8
1: Started writing EOD data
bit 9
1: Started ADC check of EOD data
bit 10
1: Started envelope check of EOD data
bit 11
1: Started C1 error check of EOD data
bit 12
1: Started C2 error check of EOD data
bit 13
1: Started to ignore dummy of EOD data
bit 14
1: Started bank fix of EOD data
bit 16
1: Started writing of RCF data
bit 17
1: Started ADC check of RCF data
bit 18
1: Started envelope check of RCF data
bit 19
1: Started C1 error check of RCF data
bit 20
1: Started C2 error check of RCF data
bit 21
1: Started to ignore dummy of RCF data
bit 22
1: Started bank fix of RCF data
bit 23
1: CRC error occurred
bit 24
1: EDC correctable warning
bit 25
1: EDC fatal error
bit 26
1: ADC parity error 2
bit 27
1: ADC parity error 3
bit 28
1: ADC parity error 4
bit 29
1: DPR parity error
bit 30
1: Repositioning is not possible
bit 31
1: Error occurred in Rec Confi
5-6. LOG Mode
5-83

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gy-8240fc

Table of Contents