Sony GY-8240UWD Maintenance Manual page 145

Dtf tape drive
Table of Contents

Advertisement

3. Removing the Motor Holder Assembly
(1) Remove the two screws and shift the MC
sensor assembly in the arrow direction.
(2) Disconnect the connector CN2 on the MC
sensor assembly.
(3) Remove the two screws to remove the motor
holder assembly.
Installation
4. Installing the Motor Holder Assembly
(1) Put the hook of a new motor holder assembly
in the sloted hole of the worm assembly and
fix it with the two screws.
(2) Connect the harness of the motor holder
assembly to the connector CN2 on the MC
sensor board and route the harness as shown
in the figure.
(3) Install the MC sensor assembly with the two
screws.
5. Installing the PA Guard
Install the PA guard with the screw.
6. Installing the Reel Motor Plate
Assembly
Install the reel motor plate assembly.
(Refer to steps 5 to 10 in Section 3-14.)
Adjustment after replacement
7. Confirming the Reel Shift Motor
Operation
(CH02: Reel Shift Motor Check)
Refer to Section 5-4-13.
GY-8240UWD
GY-8240FC
Motor holder assembly
PWH3 x 8
Hook
Worm assembly
Sloted hole
Harness
Removing/Installing the Motor Holder Assembly
PWH3 x 8
Installing the PA Guard
3-15. Reel Shift Motor Replacement
PWH3 x 8
PWH3 x 8
CN2
MC sensor
assembly
PA guard
Pin
3-59