Sony GY-8240UWD Maintenance Manual page 298

Dtf tape drive
Table of Contents

Advertisement

5-6. LOG Mode
16. ERATE+INFX (Bank unit)
Function: Displays various error rate information.
Operation: Enter "71"".
71: Error Rate Log
Displays various error rate information by one bank.
Enter the number to be displayed at Display Contents, and press ".
0: Bank Information
Number of IDs read and written
Read/Write
Number of
offsets
Physical ID
in bank
The above is displayed when bank information is selected.
Refer to the following table for the main routine flags and interruption routine flags.
The number of C2 retries and IN point retries is the (number actually performed)/(Maximum number of
retries specified by FMT).
The number of C2 errors is the number of C2 errors which have occurred in the bank. As the C2 error is
reported for every half ID in the DTF-2, up to 80 errors can be reported to 40 IDs.
5-82
Main Routine
Applicable bank No.
Flag
Interruption
Bank top
address
Routine Flag
ERATE + + + + + INFX Execution Screen
Number of IN point retries
Format ID
Number of C2 errors (ach block)
Number of
C2 retries
Number of C2 errors (ech block)
GY-8240UWD
GY-8240FC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gy-8240fc

Table of Contents