Sony GY-8240UWD Maintenance Manual page 129

Dtf tape drive
Table of Contents

Advertisement

3-11. Capstan Motor Replacement
6. Closing the SV-205 Board
Close the SV-205 board with the two screws.
7. Installing the CONFI Head Assembly
Install the CONFI head assembly.
(Refer to step 4 in Section 3-7.)
8. Cleaning
Clean the capstan motor shaft and CONFI head
surface with a cleaning cloth moistened with
cleaning fluid.
(Refer to Section 2-2-4 and 2-2-5.)
n
After cleaning, wipe with a dry cleaning cloth.
9. Installing the W Cleaner Assembly
Install the W cleaner assembly.
(Refer to steps 4 to 6 in Section 3-5.)
Adjustment after Replacement
10. Confirming the Pinch Press Clearance
Refer to Section 3-10.
11. Confirming the Tape Running
Refer to Section 4-3.
12. Performing the CONFI Head Height
Refer to Section 4-9.
13. Performing the Servo Adjustment
Refer to Section 5-9-5.
(All Motors, Tension Sensors Adj)
14. Confirming the Capstan Motor
Operation
Refer to Section 5-4-13.
(CH06: Capstan Motor Check)
3-43
GY-8240UWD
GY-8240FC

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gy-8240fc