Original Exit (Single-Sided Original Mode)
The exit gate solenoid [A] remains off, the exit gate [B] remains closed, and the
original is fed out to the right exit tray.
The speed of the motor is reduced about 30 mm from the trailing edge of the
original to ensure the originals stack neatly on the exit tray. This timing is
determined by the length of the original, and the time since the exit sensor [C]
detected the leading edge.
The transport belt motor turns off after the exit sensor [C] turns off.
SM
CÓPIA NÃO CONTROLADA
[A]
6-25
CÓPIA NÃO CONTROLADA
[B]
[C]
B070D928.WMF
ADF
B070/B071