SC998: Application Start Error
Definition [B]
Register processing does not execute for any application within 60 s after the
machine is powered on. No application starts correctly, and all end abnormally.
Possible Causes
• Software defective; change the firmware for the application that failed
• A RAM or DIMM option required by the application is not installed or not
installed correctly.
SC999: Program Download Error
Definition [B]
The program download from the SD card does not execute normally. This SC is not
logged.
Possible Causes
• Card installed incorrectly
• BCU defective
• SD card defective
• Controller board defective
• Power down during program downloading
• Wrong type of card inserted (see Section 5 "Service Tables" for downloading
procedures)