3.8.8 TONER DENSITY SENSOR

1. Remove the developer. (!3.8.2)
2. Remove the TD sensor [A] ( x 2).
3. Thoroughly clean the development unit, so no carrier particles remain in the
gap between the TD sensor and the development unit casing.
4. Install the new TD sensor
5. Install new developer and reassemble the development unit. (!3.8.2)
6. Execute SP2801 (TD Sensor Initial Setting). (!3.8.2)
7. Execute SP2962 (Auto Process Control Execution).
NOTE: Do not make any copies until you have executed SP2801 (TD Sensor
Initial Setting).