Service Program Mode Tables; Service Table Key; Copier Service Program Mode Tables - Gestetner B070 Service Manual

Table of Contents

Advertisement

SERVICE PROGRAM MODE TABLES

5.2 SERVICE PROGRAM MODE TABLES
NOTE: The Service Program Mode is for use only by customer engineers so that they can properly
maintain product quality. If this mode is used by anyone other than a customer engineer for
any reason, data might be deleted or settings might be changed. In such a case image
quality can no longer be guaranteed.

Service Table Key

Notation
[range / default / step]
Italics
*
DFU
Japan only
SEF
LEF

5.2.1 COPIER SERVICE PROGRAM MODE TABLES

SP1-nnn Feed
SP
1001
Leading Edge Registration
001
002
003
004
1002
Side-to-side Registration
001
002
003
004
B070/B071
CÓPIA NÃO CONTROLADA
[–9~+9 / +3.0 / 0.1 mm]
The default setting +3.0 can be adjusted in 0.1mm steps in the range
±9.
Comments added for reference.
An asterisk marks the SP's that are reset to their factory default
settings after an NVRAM reset.
Denotes "Design or Factory Use". Do not change this value.
The feature or item is for Japan only. Do not change this value.
Short Edge Feed
Long Edge Feed
Number/Name
Copier/LCT Paper Tray
Duplex Tray
Copier//LCT Paper Tray (Low
Speed)
Duplex Tray (Low Speed)
1st Tray (Copier Tandem Tray)
2nd Tray (Copier)
3rd Tray (Copier)
4th Tray (LCT Tray 1)
CÓPIA NÃO CONTROLADA
What it means
Function/[Setting]
Adjusts the printing leading edge
registration for feeding from the trays and
duplex tray using the trimming area
pattern (SP2-902-3, No.15).]
Use the "
/ *key to enter the minus ( –)
before entering the value.
The specification is 4
B070: [-9.0~+9.0 /-2.6 / 0.1 mm]
B071: [-9.0~+9.0 / -4.0 / 0.1 mm]
B070: [-9.0~+9.0 / -0.3/ 0.1 mm]
B071: [-9.0~+9.0 / -0.4 / 0.1 mm])
B070: [-9.0~+9.0 / -3.0 / 0.1 mm]
B071: [-9.0~+9.0 / -2.0 / 0.1 mm]
[-9.0~+9.0 / 0 / 0.1 mm]
Adjusts the printing side-to-side
registration from the 1st paper feed
station using the trimming area pattern
(SP2-902-3, No.15).
Use the "
/ *key to enter the minus ( –)
before entering the value.
Specification: 0
[-9.0~+9.0 / -0.1 / 0.1 mm]
[-9.0~+9.0 / -0.6/ 0.1 mm]
[-9.0~+9.0 / -0.3 / 0.1 mm]
[-9.0~+9.0 / -0.8 / 0.1 mm]
5-4
Rev. 06/2004
±
2 mm. ( 3-17)
±
2.0 mm. ( 3-17)
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B071

Table of Contents